Please note that these pages are meant as general instructions. While most of the information here applies to all scanners, some options may not be available on certain scanner models. Model-specific options are indicated in the text.

This section deals with EDACS SCAT systems. Click here for information on EDACS Wide and Narrow systems. Below is an example of an EDACS SCAT system from RadioReference:

<noautolink>RREDACSSCAT.png</noautolink>
150 px

And here is a conceptual layout diagram of a basic EDACS SCAT system. (Click here for a legend of the diagram.)

Programming an EDACS SCAT System

To program an EDACS SCAT system, you'll need to program the required elements in following order (click here for information on using the menu):

Create a system

  1. Go to the Program System menu and choose New System .
  2. The scanner will prompt you for the System Type. Select EDCS .
  3. The scanner will prompt you for the sub-type. Select SCAT .
  4. When the scanner prompts you confirm, tap YES .
  5. The scanner creates the system with a default name. Select Edit Name if you want to change it.
  6. If you need to change any of the system properties, you can do that now. Unless a property is Required , you can operate the system without changing the default settings.

System properties

All of these options can be found under your scanner's Program System menu. If necessary, the sub-menu and option name on each scanner are listed beside the property.

Property Option name
Required
None
Recommended
Name Edit Name
Number tag Set Number Tag
Optional
RecordBCD996XT or BCT15X: Set Record
BCD396XT or BC346XT: Not available
Automatic Gain Control (AGC) BCD396XT or BCD996XT: Set Audio AGC
BC346XT or BCT15: Not available
Delay time Set Delay Time
Available operations
Copy a system Copy System
Delete a system Delete System

Create a site

Each EDACS SCAT system must contain exactly 1 site.

  1. On the Program System menu, select the system you just created.
  2. Go to the Edit Site menu.
  3. If you need to change any of the site properties, you can do that now. Unless a property is Required , you can operate the system without changing the default settings.

Site properties

All of these options can be found under your scanner's Edit Site menu. If necessary, the sub-menu and option name on each scanner are listed beside the property.

Property Option name
Required
None
Recommended
Quick key Set Quick Key
Optional
Attenuator Set Attenuator
Hold time Set Hold Time
Location information Set Location Info
Set StateBCT15X: Set State
Other Models: Not available
Lockout Set Lockout
Modulation Set Modulation
Startup key Set Startup Key
Available operations
None

Create at least 1 frequency

Each EDACS SCAT system must contain at least 1 frequency in its site.

  1. Open the Edit Site menu.
  2. Go to the Set Frequencies sub-menu and select New Frequency .
  3. Enter at least 1 frequency for this site.
  4. If you need to change any of the frequency properties, you can do that now. Unless a property is Required , you can operate the system without changing the default settings.

Frequency properties

All of these options can be found by selecting the frequency under the Set Frequencies sub-menu. If necessary, the sub-menu and option name on each scanner are listed beside the property.

Property Option name
Required
None
Recommended
Number tag Set Number Tag
Optional
RecordBCD996XT or BCT15X: Set Record
BCD396XT or BC346XT: Not available.
Volume OffsetVolume Offset
Lockout Set Lockout
Available operations
Delete a frequency Delete Frequency